Cryopreservation of erythrocytes at –40 оС and –80 оС
Annotation
Results of cryopreservation of erythrocytes at the temperatures of –40 °C and –80 °C are presented in the article. Standard dose of erythrocytes decryopreservated after storage within 2-5 months at –40 °C was shown to be much safer and more functionally full unlike its behavior at –80 °C. The difference between low-temperature storage at –40°C and –80°C was statistically significant in terms of hemolysis level, hemoglobin content in the dose and the quantity of osmotically unstable erythrocytes. The hemolysis rate in suspensions of washed defrozen erythrocytes cryopreserved at –40 °C and at –80 °C was 0.06±0.011 and 0.53±0.125 respectively. The washed defrozen erythrocytes stored at –80 °C were shown to exhibit low hemoglobin content (18.4±1.69 g) and percentage of preserved cells (31.1±3.09) in the dose. A meaningful dependence of these indicators on a method of defreezing (in water bath at 40 °C or in the SAHARA device), and also on a method of freezing to –80 °C (linear or two-level) was not found. At the same time the content of hemoglobin in a dose of the deglycerinizated erythrocytes stored at –40 °C was 49.5±1.88 g., safety of erythrocytes – 83.8±4.09% that meets modern criteria of this medium applicability.
Keywords
Постоянный URL
Articles in current issue
- The effect of complex supplements on 100% barley malt wort fermentation process
- Using global gene pool of cattle in the formation of raw materials base for dairy industry of Black Earth region
- The prospects for freezing of Jerusalem artichoke (Helianthus tuberosus L.) tubers
- The choice of parameters for vacuum freeze-drying of dry heat-sensitive material with predetermined properties
- Competitiveness of yogurt with selenium in terms of the market for fermented milk products
- Quality of bread with hops
- Training technique in the field of the refrigeration and air conditioning based on the Worldskills standards
- Refrigerator car with nitrogen cold supply system
- Improving of packed absorption gas cleaning systems in life support systems
- Thermal performance of the refrigeration unit in the air conditioning system with the use of organofluorine compounds as refrigerants
- Circulating system of thermostatting for rotary heat exchanger with single phase hydrogen
- Earth’s climate and the transmission of earth’s heat radiation through the atmosphere
- The influence of crystallite size on electrocaloric properties of ferroelectric ceramics
- Compensation of neglected interactions while calculating freezing temperature of water-propylene glycol coolant
- Simulation of skin cryotherapy