A SIGNAL ENHANCED PORTABLE RAMAN PROBE FOR ANESTHETIC GAS MONITORING
Annotation
The spontaneous Raman scattering technique is an excellent tool for a quantitative analysis of multi-species gas mixtures. It is a noninvasive optical method for species identification and gas phase concentration measurement of all Raman active molecules, since the intensity of the species specific Raman signal is linearly dependent on the concentration. Applying a continuous wave (CW) laser it typically takes a few seconds to capture a gas phase Raman spectrum at room temperature. Nevertheless in contrast to these advantages the weak Raman signal intensity is a major drawback. Thus, it is still challenging to detect gas phase Raman spectra in alow-pressure regime with a temporal resolution of only a few 100 ms. In this work a fully functional gas phase Raman system for measurements in the low-pressure regime (p ≥ 980 hPa (absolute)) is presented. It overcomes the drawback of a weak Raman signal by using a multipass cavity. A description of the sensor setup and of the multipass arrangement will be presented. Moreover the complete functionality of the sensor system will be demonstrated by measurements at an anesthesia simulator under clinical relevant conditions and in comparison to a conventional gas monitor.
Keywords
Постоянный URL
Articles in current issue
- METHODS AND TECHNIQUE FOR THERMOPOWER AND ELECTRICAL CONDUCTIVITY MEASUREMENTS OF THERMOELECTRIC MATERIALS AT HIGH TEMPERATURES
- STUDY OF BIREFRINGENCE INFLUENCE ON IMAGE QUALITY OF PHOTOLITHOGRAPHY SYSTEMS IN VIEW OF PARTIALLY-COHERENT LIGHT SOURCE
- EDGE EFFECT MODELING AND STUDY FOR THREE-CHIP RGB LIGHT-EMITTING DIODES
- NON-INTRUSIVE GAS-PHASE THERMOMETRY FOR INDUSTRIAL OXY-FUEL BURNERS
- A SIGNAL ENHANCED PORTABLE RAMAN PROBE FOR ANESTHETIC GAS MONITORING
- COMPENSATION OF OUTPUT SIGNAL TEMPERATURE DEPENDENCE IN HOMODYNE DEMODULATION TECHNIQUE FOR PHASE FIBER-OPTIC SENSORS
- STUDY OF REFLECTION COEFFICIENT DISTRIBUTION FOR ANTI-REFLECTION COATINGS ON SMALL-RADIUS OPTICAL PARTS
- BEND-INDUCED LOSSES IN A SINGLE-MODE MICROSTRUCTURED FIBER WITH A LARGE CORE
- PROTECTIVE COATINGS OF FIBER BRAGG GRATING FOR MINIMIZING OF MECHANICAL IMPACT ON ITS WAVELENGTH CHARACTERISTICS
- TWO-MOTOR ELEVATION DRIVE OF THE PRECISION TWIN TELESCOPE
- ELECTRON DIFFRACTION STUDY OF GRAPHENE LAYERS STRUCTURE ON CONDUCTIVE AND SEMI-INSULATING 6H-SIC (0001) SUBSTRATES
- SAXSEV 2.1 CROSS-PLATFORM APPLICATION FOR DATA ANALYSIS OF SMALL-ANGLE X-RAY SCATTERING FROM POLYDISPERSE SYSTEMS
- NEW BIOTESTING METHOD WITH THE APPLICATION OF MODERN IMPEDANCE TECHNOLOGIES
- ENERGY CONSUMPTION MONITORING OF SMART GRID BASED ON SEMANTIC STREAM DATA ANALYSIS
- METHODS OF POLYMODAL INFORMATION TRANSMISSION
- FREQUENCY OPTIMIZATION FOR SECURITY MONITORING OF COMPUTER SYSTEMS
- MODEL OF PROVIDING WITH DEVELOPMENT STRATEGY FOR INFORMATION TECHNOLOGIES IN AN ORGANIZATION
- METHODS FOR SOLVING LINEAR PROGRAMMING PROBLEMS WITH ADDITIONAL RESTRICTIONS TO THE PARTICULAR VARIABLES
- INTERVAL ADDITIVE PIECEWISE POLYNOMIAL TIME OPERATION MODEL OF HUMAN-OPERATOR IN A QUASI-FUNCTIONAL ENVIRONMENT
- OBLIQUE SHOCK WAVE REFLECTION FROM THE WALL
- OPTIMIZATION OF THE COVERAGE ZONE FOR A CELLULAR NETWORK BASED ON MATHEMATICAL PROGRAMMING
- INTERFERENCE OF COUNTERPROPAGATING SHOCK WAVES
- COMPACT REPRESENTATION OF THE PRIORITY MATRIX WITH HIGH DIMENSIONALITY
- MERIDIONAL COMA OF NEGATIVE ANASTIGMATIC LENSES AT THE FINAL POSITION OF AN OBJECT
- LUMINESCENCE OF CADMIUM SULFIDE QUANTUM DOTS IN FLUOROPHOSPHATE GLASSES