A method of describing the saturation line based on the apparent heat of vaporization and Clausius-Clapeyron equation
Annotation
Introducing the apparent heat of evaporation in the structure of Clausius-Clapeyron equation is shown to allow describing the steam branch of the phase equilibrium lines from the triple point to the critical point. In the neighborhood of the triple point a transition to a state close to the ideal-gas one is provided, and in neighborhood of critical point "completed" scaling, according to which the behavior of the average diameter is determined by the exponent 2β (where βis the critical index of the coexistence curve) is enforced. The method in question is tested on the description for the steam branch of R218 refrigerant phase equilibrium lines. The description accuracy of the vapor pressure density on the line of elasticity and the apparent heat of vaporization for R218 refrigerant corresponds to the experimental one. It is shown that near the triple point the density of R218 is inflated by 0.2% compared to the density calculated on the basis of the model for an ideal gas, and the apparent heat of vaporization calculated on the basis of the proposed method differs from the values calculated by the model for an ideal gas by only 0.03%.
Keywords
Постоянный URL
Articles in current issue
- The use of lactic acid bacteria for the preparation of sour ales
- Prospects of biologically active additives in food products for elderly nutrition
- Enlargement of product assortment based on the dairy whey of dietary preventive nutrition
- The 24th General Annual Meeting of the International Academy of Refrigeration
- Results of the IAR’s work in 2016-2017 (Report of the IAR President at the 24th General Annual Meeting on April 27, 2017). List of members of the International Academy of Refrigeration (as of 27.04.2017)
- The hybrid cooling system of onboard infrared detectors on the basis of vortex and thermoelectric effects
- Improving the efficiency of vapor refrigerating machine with screw compressors at capacity control
- Energy efficiency analysis of incorporating heat pumps and solar collectors in the composition of the absorption refrigerating machines in a centralized air-conditioning systems
- Retrofitting centrifugal refrigerating machines and compressors to HFC refrigerants in Belarus
- True parameters of boiling refrigerants in tubes and channels
- The use of the capacitive sensors for the study of condensation processes in the short low-temperature range heat pipes. Calibration and measurement
- Estimation of the freezing process for lake water in the near-contact section of the 5G borehole with subglacial lake Vostok (Antarctica)
- Exergy analysis of freeze concentration unit
- Analysis and design of multicomponent systems in biotechnology industry in the context of uncertainty based on entropy potential quality indicators